ÁöÁß¼öÆò º¯À§ °èÃø Àåºñ Inclinometer Probe System
  ÁöÁß °æ»ç ÃøÁ¤¿ë ÄÉÀ̽Ì
ABS Inclinometer Casing
  °¡¼Óµµ¼¾¼­
Accelerometer
  °£±Ø ¼ö¾Ð ¼¾¼­
Piezometer, Water Level Indicator
  ÁöÁß Ä§ÇÏ °èÃø ¼¾¼­
Settlement Sensors
  ÁöÁß º¯À§ ÃøÁ¤ ¼¾¼­
Extensometer
  ±¸Á¶¹° °æ»ç °èÃø ¼¾¼­
Structure Tiltmeters
  ¼öÁ÷,¼öÆò º¯À§ °èÃø¿ë ÀüÀÚ ºö¼¾¼­
EL Beam Sensors
  Åä¾Ð°è¿Í ¾Ð·Â ¼¿
Pressure Cells
  Áøµ¿Çö½Ä ½ºÆ®·¹ÀÎ °ÔÀÌÁö
Vibrating Wire Strain Gages
  ÇÏÁß°è
Load Cell
  ±Õ¿­ ÃøÁ¤ ¼¾¼­
Crack Gages
  ±âŸ Ư¼ö °èÃø±â
Goodman Jack
  µ¿Àûµ¥ÀÌÅͷΰÅ
Dynamic Data Logger
  ÀÚµ¿È­ °èÃø ½Ã½ºÅÛ
Data Logger
  ÈÞ´ë¿ë ÃøÁ¤±â
Read Outs
  ±×¸²À» ÅëÇÑ °èÃøÀÇ ÀÌÇØ
Field Installation
  ±â¼ú¸Þ¸ð
Technical Notes
  ȸ»ç¾àµµ
Where we are
 
  ÁöÁß ¼öÆòº¯À§ °èÃø Àåºñ (°æ»ç°è Inclinometer)
°æ»ç°è ¼¾¼­ (Digitilt Inclinometer Probe)
1. ÀϹݻçÇ×
 
¼³Ä¡µÈ ÁöÁß °æ»ç°è ÄÉÀ̽ÌÀÇ ¼öÆò º¯À§·® °ËÃâ¿¡ »ç¿ëµÈ´Ù.
ÁÖ¿ä Æ¯Â¡Àº °íÁ¤¹Ðµµ, ºü¸¥ ÀÀ´ä¼Óµµ, Àå±â ¾ÈÁ¤¼ºµî ÀÌ·ç Çì¾Æ¸± ¼ö ¾ø´Ù.
ÀܰíÀåÀÌ °ÅÀÇ ¾ø¾î »ç¿ëÀÚ°¡ Ç׽à ¾È½ÉÇϰí ÇöÀåÀÏ¿¡ Ãæ½ÇÇÒ ¼ö ÀÖ´Ù.
´Ü, Àåºñ¸¦ À̵¿Çϰųª °ø³» »ðÀԽà ¼¾¼­ÀÇ ¸Á½ÇÀÌ ÀÖÀ» ¼ö ÀÖÀ¸¹Ç·Î ±Þ°ÝÇÑ Ãæ°ÝÀ» ÁÖÁö ¾Êµµ·Ï ÁÖÀÇÇÏ¿©¾ßÇÑ´Ù.
2. Á¦Ç° »ç¾ç
 
¡¤ ¼¾¼­ ¹æ½Ä : ¾çÃà ¼­º¸ °æ»ç°è ¼¾¼­ ³»Àå
¡¤ ¹ÙÄû°£ °Å¸® : 500§®
¡¤ »ç¿ë¹üÀ§ : ¼öÁ÷À¸·ÎºÎÅÍ ¡¾53¡Æ
¡¤ ºÐÇØ´É : 500§® ´ç 0.02§®
¡¤ ¹Ýº¹µµ : ¡¾0.01%FS
¡¤ ½Ã½ºÅÛ Á¤È®µµ : ¡¾ 0.25§®/ȸ
3. Á¦Ç° ¹øÈ£
 
Digitilt Metric Probe .................50302510
°æ»ç°è °èÃø¿ë ÄÉÀ̺í (Control Cable)
1. ÀϹݻçÇ×
 
ÇÁ·Îºê¿¡ ¿¬°áÇÏ¿© ½ÅÈ£¸¦ µ¥ÀÌÅ͸ÞÀÌÅÍ¿¡ Àü¼ÛÇÑ´Ù.
¿À·¡ »ç¿ëÇÏ¿©µµ ½±°Ô ´â°Å³ª ²÷¾îÁöÁö ¾Ê´Â´Ù. Àß ¾ûŰÁöµµ ¾Ê´Â´Ù.
³»±¸¼ºÀÌ ¶Ù¾î³ª°í ±æÀ̰¡ Ç¥½ÃµÈ °í¹«¸¶Å· ÀÚ¸®´Â ¹Ý¿µ±¸ÀûÀÌ´Ù.
ÇǺ¹ ÀçÁúÀº ¹°¿¡ ´ê¾Æµµ Àß ¹Ì²ô·¯ÁöÁö ¾Êµµ·Ï °í¾ÈµÇ¾ú´Ù.
2. Á¦Ç° »ç¾ç
 
¡¤ ³ë¶û»ö 0.5m¸¶Å· Ç¥½Ã
¡¤ »¡°­»ö 1.0m¸¶Å· Ç¥½Ã
3. Á¦Ç° ¹øÈ£
 
Control Cable, Metric .......................................50601010
PulleyAssembly(70°ú85§®ÄÉÀ̽̿¡ÀûÇÕ) .............51104606
4. ¿ÏÁ¦Ç° ¹øÈ£
 
ÄÉÀ̺í 30m .....................................................50601030
ÄÉÀ̺í 50m .....................................................50601050
ÄÉÀ̺í 100m ...................................................50601100
°æ»ç°è ÃøÁ¤±â (Digitilt DataMate Readout)
1. ÀϹݻçÇ×
 
º» ÃøÁ¤±â·Î´Â Slope Indicator»ç¿¡¼­ »ý»êÇÏ´Â ¸ðµç Probe¿Í 100% ȣȯÀÌ µÇ¸ç µ¥ÀÌÅÍ ¼öÁý°ú ÀúÀå ±×¸®°í PC·Î µ¥ÀÌÅ͸¦ Àü¼ÛÇÏ´Â ±â´ÉÀÌ ÀÖ´Ù.
°¡º±°í ÈÞ´ëÇÏ±â ÆíÇÏ´Ù. ÇÚµå ½ºÀ§Ä¡°¡ Æ÷ÇԵǾî ÀÖ¾î °èÃøÀÌ °£´ÜÇÏ´Ù.
PC·Î µ¥ÀÌÅÍ Àü¼ÛÇÏ´Â ÇÁ·Î±×·¥Àº DMM ÀÌ´Ù.
¿©·¯°³ÀÇ ´©Àû º¯À§¸¦ °èÃøÇÏ°í ½Í´Ù¸é PN50310001 Digipro ÇÁ·Î±×·¥ (Window XP±Þ) »ç¿ëÀ» ±ÇÀåÇÑ´Ù.
2. Á¦Ç° »ç¾ç
 
¡¤ ȣȯ¼º : ¼öÁ÷, ¼öÆò, µÚƲ¸² ÃøÁ¤ ÇÁ·Îºê¿Í °Ç¹°±â¿ï±â ¼¾¼­
¡¤ ÃÖ¼Ò °èÃø °£°Ý : 0.5m
¡¤ ÀúÀå ¿ë·® : 10k data points
¡¤ ÀÛµ¿ ½Ã°£ : ¿¬¼Ó »ç¿ë½Ã 16½Ã°£
3. Á¦Ç° ¹øÈ£
 
Digitilt DataMate Readout ........50310900