ÁöÁß¼öÆò º¯À§ °èÃø Àåºñ Inclinometer Probe System
  ÁöÁß °æ»ç ÃøÁ¤¿ë ÄÉÀ̽Ì
ABS Inclinometer Casing
  °¡¼Óµµ¼¾¼­
Accelerometer
  °£±Ø ¼ö¾Ð ¼¾¼­
Piezometer, Water Level Indicator
  ÁöÁß Ä§ÇÏ °èÃø ¼¾¼­
Settlement Sensors
  ÁöÁß º¯À§ ÃøÁ¤ ¼¾¼­
Extensometer
  ±¸Á¶¹° °æ»ç °èÃø ¼¾¼­
Structure Tiltmeters
  °æ»ç ÃøÁ¤¿ë Á¤¹Ð¼¾¼­
Inclinometer
  ÄÉÀÌºí º¯À§°è
Cable Extensometer
  ¼öÁ÷,¼öÆò º¯À§ °èÃø¿ë ÀüÀÚ ºö¼¾¼­
EL Beam Sensors
  Åä¾Ð°è¿Í ¾Ð·Â ¼¿
Pressure Cells
  Áøµ¿Çö½Ä ½ºÆ®·¹ÀÎ °ÔÀÌÁö
Vibrating Wire Strain Gages
  ÇÏÁß°è
Load Cell
  ±Õ¿­ ÃøÁ¤ ¼¾¼­
Crack Gages
  ±âŸ Ư¼ö °èÃø±â
Goodman Jack
  °Ç¼³Áøµ¿, ¼ÒÀ½ ÃøÁ¤±â
MiniSeis
  ÀÚµ¿È­ °èÃø ½Ã½ºÅÛ
Data Logger
  ÈÞ´ë¿ë ÃøÁ¤±â
Read Outs
  ±×¸²À» ÅëÇÑ °èÃøÀÇ ÀÌÇØ
Field Installation
  ½ÅÁ¦Ç° ½Å±â¼ú ¼Ò°³
Technical Notes
  ȸ»ç¾àµµ
Where we are
 
  °æ»ç ÃøÁ¤¿ë Á¤¹Ð¼¾¼­ (Inclinometer)
1. Á¦Ç°ÁÖ¿äÆ¯Â¡
 
¡¤ Ư¼ºÀÌ ¾ÈÁ¤ÀûÀÎ Á÷¼±Çü ¼¼¶ó¹Í ±â¿ï±â ¼¾¼­ »ç¿ë
¡¤ °Ç¼³ Áøµ¿¿¡µµ ¾ÈÁ¤ÀûÀÎ µ¥ÀÌÅÍ Ãâ·Â ¼¾¼­ žÀç
¡¤ °í(ÍÔ) Á¤µµ(Óø)ÀÇ ºÐÇØ´É Á¦°ø
¡¤ ÀÌ»óÀûÀÎ Á¿ì´ëĪ °¢µµ ¼¾¼­ ¡¾5¡Æ ¡¾10¡Æ
¡¤ ±¤¹üÀ§ÇÑ ¿Âµµ ´ë¿ª¿¡¼­ »ç¿ë°¡´É -55¡É~+125¡É
2. ÀÀ¿ë Á¦Ç° ±º(ÏØ)
 
¡¤ º®Ã¼ ¹× ½½¶óºê ºÎÂø½Ä °æ»ç°è
¡¤ °íµµÈ­ »ê¾÷¼³ºñÀÇ °æ»çµµ ÃøÁ¤¼¾¼­
¡¤ ±¸Á¶¹° º¯À§ °¨ÁöÃøÁ¤ ¼¾¼­ (EL Beam Sensor)
¡¤ ¼öÆò ¸Å¼³ ½Ä °æ»ç°è
¡¤ ÁöÁß ¸Å¼³ ½Ä °æ»ç°è (In Placement Inclinometer)


<Á¦Á¶ °úÁ¤»ó °ø±ÞÁ¦Ç°Àº ½Ç¹°»çÁø°ú ¾à°£ ´Ù¸¦ ¼ö ÀÖ½À´Ï´Ù.>

3. Á¦Ç°»ç¾ç
Items

GV-2401 Tiltmeter

Comments/units

GV-2402 IPI

Comments/units
Range

-5 to +5

arcdeg near linear

-11 to +11

arcdeg near linear

Range

-3 to +3

arcdeg linear

-10 to +10

arcdeg linear

Resolution

<5

arcsec typical

<3

arcsec typical

Repeatability

<0.002

arcdeg typical

<0.005

arcdeg typical

Linearity

<1% @3¡Æ

CCW & CW

<2% @ 100

% CCW & CW

Linearity

<0.5% @2¡Æ

CCW & CW

<0.1 @ 100

arcdeg CCW & CW

Linearity

<0.25% @1¡Æ

CCW & CW

<0.05 @ 50

arcdeg CCW & CW

Symmetry

<2% @3¡Æ

CCW & CW

<0.005 @ 0.50

arcdeg CCW & CW

Response time

<100

msec * #

<40 mSec

msec * #

Time constant

<1000 msec

msec msec ** #

<150 mSec

msec msec ** #

Tot. setting time

<2 sec

Sec *** #

<300 mSec

mSec see notes*#

Temperature

-55 to +125

Deg C operational

-55 to +125

mSec see notes**#

Temperature

-55 to +125

Deg C storage

-55 to +125

mSec see notes***#

Construction

ceramic

Hermetic

ceramic

Hermetic
* Elapsed time until the sensor reacts to a tilt disturbance.
** Elapsed time from the end of disturbance until the sensor is within 90% of its final output.
*** Elapsed time from the end of disturbance until the sensor is at STEADY STATE output.
# Based on standard non-modified electrolyte.
# Viscosity of the electrolyte may be modified to filter out vibration.